PRODUCT SUPPORT 800.927.2120 8am - 6pm EST
LUDLOW
Thermostatic Control Valve Trim
INSTALLATION GUIDELINES
Page 1 of 2
10.30.2013
These guidelines have been prepared for the professional contractor to aid in the installation of:
LUDLOW THERMOSTATIC CONTROL VALVE TRIM WITH METAL CROSS HANDLE (STYLE#
LDTH01) & METAL LEVER HANDLE (STYLE # LDTH10)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
SEE SERVICE PART DOCUMENT FOR PART ORDERING, AVAILABLE ON WATERWORKS.COM
Metal Cross Handle
Style No. LDTH01
Metal Lever Handle
Style No. LDTH10
SPECIFICATIONS:
Control Valve Rough-in Depth Minimum: 3-1/4"
Control Valve Rough-in Depth Maximum: 4-1/4"
Hot Limit Safety Stop: On Thermostatic Valve
REQUIRED PLUMBING DETAILS:
Universal 1/2" Thermostatic Valve
STYLE # GUTH56
IMPORTANT:
¾ NOTE: The screws on the front of the trim plate are
aesthetic only and do not serve any mechanical
purpose and should not be removed.
¾ To ensure this product is installed properly, you
must read and follow these guidelines.
¾ The owner/user of this product must keep this
information for future reference.
¾ This product is intended to work with the
Waterworks Universal 1/2" Thermostatic Valve
(GUTH56R) which features anti-scald protection.
The risk of scalding exists until the installer has
properly calibrated/adjusted the temperature
setting and set the integrated high limit stop on the
valve prior to final trim installation.
¾ Be sure your installation conforms to federal state,
and local codes. In the State of Massachusetts, all
installations must comply with the rules and
regulations set forth within 248 CMR.
¾ This thermostatic valve trim only mixes hot and cold
water. It does not have volume control or shut-off
capabilities. A diverter or wall valve (sold
separately) control on/off/volume and must be
installed for each fitting that will have water flowing
to it. This valve trim cannot be used directly with a
diverting tub spout.
¾ This product must be installed by a professional
licensed contractor and must be onsite prior to
rough-in, this allows the installer to visualize the
installation.
¾ Inspect this product to ensure you have all the parts
required for proper installation.
¾ Use only a strap wrench or protected/smooth-jaw
wrench on any finished surface.
¾ The use of certain plumber's putty may stain stone
or tile surfaces.
TEMPERATURE CALIBRATION:
¾ The risk of scalding exists until the installer has
properly calibrated/adjusted the temperature
setting prior to final trim installation.
1. Remove the tile guard and threaded tube. Slide the
o-ring and limit stop up on the cartridge stem. DO
NOT REMOVE OR DAMAGE THE O-RING. See
Figure 1.
Figure 1
Limit Stop
O-Ring
Limit Stop Pin
Clockwise - Cold
Counter Clockwise - Hot
2. Turn on the water supply and a wall valve to run
water through the thermostatic valve.
3. Slowly rotate the cartridge stem clockwise to attain
full cold then rotate it counter-clockwise to attain
full hot. Verify a full range of temperature exists.
NOTE: It is approximately 3/4 of a rotation from full
cold to full hot.
4. With the water running, rotate the cartridge stem to
the adjust the temperature to the maximum desired
bathing temperature, verified with a thermometer.
5. Slide the limit stop back onto the cartridge stem,
making sure to properly align it with the pin on the
cartridge bonnet. Slide the o-ring back to its original
position to prevent the limit stop from sliding off the
stem then turn the water off. See Figure 2
Figure 2
Align limit stop to
the pin.
Slide o-ring down
to hold limit stop.
Page view 0